Generator set data sheet
- Engine Specifications 1.800 r.p.m.
- Rated Engine Output: 37,22kW prp ; 42,81kW standby
- Manufacturer: FORD
- Model: LSG635
- Engine Type: 4-stroke Miller Cycle
- Injection Type: Carburization
- Aspiration Type: Natural
- Number of cylinders and arrangement: 6-V
- Bore and Stroke: 92,5 x 86,7 mm
- Displacement: 3,5 L
- Cooling System: Liquid (water + 50% glycol)
- Lube Oil Specifications: API ≥SH, SAE 10W-30
- Compression Ratio: 11,8
- Fuel Consumption 100% PRP: 447.73 cfh
- Total oil capacity including tubes, filters 5,68 L
- Governor Type Electrical
- Air Filter Type Dry
- Natural Gas engine
- 4-stroke cycle
- Water-cooled
- 12V electrical system
- Dry air filter
- Radiator with pusher fan
- HTW sender
- LOP sender
- Electronic governor
- Hot parts protection
- Moving parts protection
- Generator: STAMFORD
- Model: S1L2.J1
- Poles: 4
- Connection type (standard): Star-series
- Mounting type: S-3 11"1/2
- Insulation: H class
- Enclosure (according IEC-34-5): IP23
- Exciter system: Self-excited, brushless
- Voltage regulator: A.V.R. (Electronic)
- Bracket type: Single bearing
- Coupling system: Flexible disc
- Coating type: Standard (Vacuum impregnation)
- - SOUNDPROOFED VERSION.
- Steel chassis
- Anti-vibration shock absorbers
- External emergency stop switch
- Bodywork made from high quality steel plate
- High mechanical strength
- Low noise emissions level
- Soundproofing provided by high-density volcanic rock wool
- Epoxy polyester powder coating
- Full access for maintenance (water, oil and filters, no need to remove the canopy)
- Reinforced lifting hooks for crane hoisting
- Chassis drain plug
- Steel residential silencer -35db(A) attenuation.
- IP Protection according to ISO 8528-13:2016
- - GAS RAMP.
- Gas filter
- Double solenoid valve
- High pressure regulator
- Primary pressure regulator
- Low pressure switch
- Inlet pressure manometer
- Outlet pressure manometer
- Special Start/Stop sequence
- High pressure switch (Optional)
- - ELECTRICAL SYSTEM.
- Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
- Adjustable earth leakage protection (time & sensitivity) standard in M5 and AS5, with thermal magnetic protection
- Battery charger (standard on gensets with automatic control panels)
- Heating resistor (standard on sets with automatic control panels)
- Battery charger alternator with ground connection
- Starter battery/ies installed (cables and bracket included)
- Ground connection electrical installation with connection ready for ground spike (not supplied)
- Battery Switch (Optional)
- - EXHAUST SYSTEM.
- Exhaust Gas Flow: 6,7 m3/min
- Maximum allowed back pressure: 20,32 kPa
- - NECESSARY AMOUNT OF AIR.
- Intake air flow: 132 m3/h
- - STARTING SYSTEM.
- - FUEL SYSTEM
- Fuel Oil Specifications: Natural Gas
- - DIMENSIONS.
- Length: 2.750 mm
- Height: 1.760 mm
- Width: 1.100 mm
- Sound pressure level: 68 ± 2,4 dB(A)@7m
Length (A)275108.27
Width (B)11043.31
Height (C)17669.29
Weight with fluids in radiator and crankcase
0
0