Generator set data sheet
- Engine Specifications 1.800 r.p.m.
- Rated Engine Output: 565kW prp ; 673kW standby
- Manufacturer: PSI
- Model: 31.8L
- Engine Type: 4-stroke Otto Cycle
- Injection Type: Carburization
- Aspiration Type: Turbocharged and after-cooled
- Number of cylinders and arrangement: 12-V
- Bore and Stroke: 150 x 150 mm
- Displacement: 31,8 L
- Cooling System: Liquid (water + 50% glycol)
- Lube Oil Specifications: API CD/≥CF, SAE 15W40
- Compression Ratio: 10,5:1
- Fuel Consumption ESP: 2170 kW
- Fuel Consumption 100% PRP: 1877 kW
- Fuel Consumption 75 % PRP: 1473 kW
- Fuel Consumption 50 % PRP: 1078 kW
- Fuel Consumption 25 % PRP: 687 kW
- Total oil capacity: 122 L
- Total coolant capacity: 176,2 L
- Governor Type Electrical
- Air Filter Type Dry
- Natural Gas engine
- 4-stroke cycle
- Water-cooled
- 24V electrical system
- Dry air filter
- Radiator with pusher fan
- HTW sender
- LOP sender
- Electronic governor
- Hot parts protection
- Moving parts protection
- Generator: STAMFORD
- Model: HCI544E
- Poles: 4
- Connection type (standard): Star-series
- Mounting type: S-0 18''
- Insulation: H class
- Enclosure (according IEC-34-5): IP23
- Exciter system: Self-excited, brushless
- Voltage regulator: A.V.R. (Electronic)
- Bracket type: Single bearing
- Coupling system: Flexible disc
- Coating type: Standard (Vacuum impregnation)
- - OPEN SET VERSION.
- Emergency stop button
- Steel chassis
- Anti-vibration shock absorbers
- Steel industrial silencer -15db(A) attenuation
- Steel residential silencer -35db(A) attenuation. (Optional)
- - GAS RAMP.
- Manual shut-off valve
- Gas filter
- Double solenoid valve
- High pressure regulator
- Primary pressure regulator
- Low pressure switch
- High pressure switch
- Valve (tightness) testing system
- Inlet pressure manometer
- Outlet pressure manometer
- Special Start/Stop sequence
- - ELECTRICAL SYSTEM.
- Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
- Adjustable earth leakage protection (time & sensitivity) standard in M5 and AS5, with thermal magnetic protection
- Battery charger (standard on gensets with automatic control panels)
- Heating resistor (standard on sets with automatic control panels)
- Battery charger alternator with ground connection
- Starter battery/ies installed (cables and bracket included)
- Ground connection electrical installation with connection ready for ground spike (not supplied)
- Battery Switch (Optional)
- - EXHAUST SYSTEM.
- Maximum exhaust temperature: 639 ºC
- Exhaust Gas Flow: 115 m3/min
- Maximum allowed back pressure: 10,2 kPa
- - NECESSARY AMOUNT OF AIR.
- Intake air flow: 2220 m3/h
- Cooling Air Flow: 30,72 m3/s
- Alternator fan air flow: 1,312 m3/s
- - STARTING SYSTEM.
- Starting power: 11,7 kW
- Starting power: 15,91 CV
- Auxiliary Voltage: 24 Vdc
- - FUEL SYSTEM
- Fuel Oil Specifications: Natural Gas
- - DIMENSIONS.
- Length: 4.460 mm
- Height: 2.670 mm
- Width: 2.100 mm
- Maximum shipping volume: 25,01 m3
- Weight with liquids in radiator and sump: 6.423 kg
Length (A)446175.59
Width (B)21082.68
Height (C)267105.12
Weight with fluids in radiator and crankcase
6423,00
14162.715